Automatic Sliding X-ray hospital Door
hospital door, hospital sliding door, medical sliding door , automatic medical airtigh door, clean room door ,operating theaters door
Hospital door
Medical sliding door , each door has a single whole steel plate , lined with aluminum profile inner frame and high strength honeycomb panels , surrounded by high quality stainless steel shut perfect treatment , high dimensional accuracy , closed surface made of high quality EPDM special rubber seal to be perfect seamless seal , Bao steel steel board used in all high-quality cold-rolled steel , the surface with high-quality weather-resistant color pure polyester electrostatic powder coating , its performance in line with GB5237.4-2000 standard (in line with European standards QUALICOA D), and the development of a variety of wood effect , Door Press (medical diagnostic X-ray emission prevention health protection requirements ) lining thickness corresponding stereotype . protective harness toward lining 2mmpb thickness , the thickness of the other 1mmbp protection , The vertical axis hinge design unique , different from the conventional hinge , changing the point of impact to avoid sagging door , making more durable protective door , you open smoothly
Automatic Medical Airtight Doors with airtight , Sound insulation , thermal insulation , fire protection , radiation protection
1 Using a small volume , high-power brushless DC motor , frequent opening and closing , also can be long-term trouble-free operation
2. The sides of the door equipped with professional vacuum airtight tape , using a unique compression technology to ensure the door when the door is closed with the close coordination to achieve reliable sealing effect
3. With foot switch and special handle , health care workers to open the door easily , when power outage it can be opened by handle
4. The Safety sensors can effectively prevent the clip people , also can be set to automatic door sensor drive from indoor
5. Also can be opened easily by a remote control
6. The user can set the sensor effects , the flexibility to set the sensor operation mode according to the doctor`s work habits and characteristics of various types of surgery , in order to achieve the best results
Designed for clean room environments such as hospital operating rooms , pharmaceutical production plants, precision equipment factories, food shop , laboratory access port
Technical parameters
Power Voltage : 220V/50HZ
Power consumption : <150w
Door weight :<200KG
Opening/Closing speed : 20-60cm/sec
Closed way: Auto/induction
Safety Light Beam Switch :
This is which accord with the European standards , with a completely interference immunity . Also accord with ESC standards and in line with the French government about the workplace regulations require automatic doors
Accord with German regulations concerning the outer doors of power starting
hospital door, hospital sliding door, medical sliding door , automatic medical airtigh door, clean room door ,operating theaters door SHENZHEN HONGFA AUTOMATIC DOOR CO., LTD , https://www.hongfahss.com
1, before the operation should be cleared of internal impurities.
2. The power distribution room should be cleaned at least once a year or more. When cleaning, vacuum cleaners can be used to suck indoor dust.
3, the outside of the box must also be cleaned more than once a year, wipe it.
Second, humidifier inspection and maintenance:
The water storage in the humidifier should be replaced once a month to ensure that the water quality is clean. The humidifying water tray should be cleaned once a month to ensure smooth water flow.
Third, check the over-temperature protector:
During operation, the over-temperature protection setting is the highest value plus 20°C~30°C. When the temperature in the test chamber rises to the over-temperature protection set point, the heater power supply is stopped, the over-temperature warning light is on but the fan is still running. If it is running for a long time and unattended, please be sure to check the over-temperature protection device before operation. Set it properly.
Fourth, the condenser dust removal:
The condenser should be maintained on a regular monthly basis. Vacuum cleaners should be used to suck dust from the condenser heatsink mesh or use high-pressure air to remove dust.
Fifth, wet ball test cloth replacement:
When the surface of the test cloth is not clean or hardened, or after the temperature control is finished, the test cloth must be replaced before continuing the temperature and humidity sphericity control. The test cloth is replaced about three months. When replacing, wipe the temperature measuring body with a cleaning cloth. When replacing the new test cloth, clean it first.
VI. Inspection and adjustment of wet bulb water level:
The water level of the stagnant water tank should not be too high, so that the water overflows the water collection tube or is too low to allow the wet ball test cloth to absorb water abnormally. The accuracy of the wet ball can be maintained at approximately six full minutes. Adjust the water level of the stagnant water tank to adjust the height of the water tank.
To sum up, only the correct cleaning and maintenance can make the constant temperature and humidity test chamber play its best performance and maximum function.
High-Low Temperature Environmental Chambers Use Safety Notes High-low temperature environmental chambers are suitable for testing and determining the parameters and performance of electronic electricians, materials, and other products subjected to changes in temperature, high temperature, low temperature, and constant temperature tests. It is also an essential test equipment for aviation, automotive, home appliances, and scientific research.
When using the high-low temperature test box, do not connect the power supply of the test sample to the power of the device unless the device reserves the power interface of the test sample, otherwise it will increase the power supply load of the device. It is forbidden to test flammable, explosive, highly corrosive, and radiated items. Please do not move the equipment during power-on or during operation.
The power supply is a three-phase, five-wire system. The equipment cables are four-wire, three-phase, one neutral, and one ground. Neutral cables must be distinguished when installing the equipment. Because part of the equipment load and control system are single-phase, miswiring the neutral line will cause the equipment to fail to work and be damaged. The equipment grounding line has a grounding column to ensure that it is well grounded and safe and reliable to use. If the user site and other factors require the extension of the cable, make sure that the extension cord and power supply used to meet the power requirements of the product.
The high and low temperature test chamber will generate a lot of heat during use. Therefore, it is necessary to install the device in a well-ventilated place. At the same time, this device must not be exposed to inflammable and explosive materials, strong magnetic and strong vibration environments during the test.
The high and low temperature test chambers are either extremely hot or very cold when operated at high or low temperature. During the test or just after the test, if you need to open the door, you have to be very careful. It is necessary for the staff to bring special protective materials such as anti-frozen and high-temperature gloves to avoid burns or frostbite. If not, do not Open the door. When the freezer is in operation, the temperature of the exhaust copper pipe is also high. Please do not touch it during operation to avoid burns.
First, clean and maintain the outside of the high and low temperature environmental test box inside: